NOTE:
Any changes to maximize eye relief will require readjustment of the diopter rings.
9. While observing an image through the device, adjust the objective lens focus (Figure 3-1) until the
image becomes sharp and clear.
10. To ip the device up, place your hand under the goggles, grasp the goggles and rotate them up and
backwards until the latch is rmly engaged.
NOTE:
The PVS-7 will turn o automatically when ipped up. The PVS-7 will not turn on automatically
when ipped back down; you will need to turn it on manually.
11. To ip the device down, grasp the goggles and rotate them down and forwards until the latch is
rmly engaged.
12. To resume operation, turn the switch to the RESET/ OFF position, then to the ON position.
C. Hand-Held Operation
CAUTION:
Operate the PVS-7 only in dark environments. If you need to operate the device in daylight,
always use the lens cap to cover the objective lens.
NOTE:
When using the PVS-7 without a mounting device, always use the neck cord.
1. Verify that the batteries are installed per paragraph 3.3.1, B.
2. Turn the RESET/ OFF-ON-IR/ PULL switch ON.
3. Adjust the interpupillary distance (Figure 3-1) by sliding the eyepieces together or apart so that each
eye can observe the entire eld of view at the same time. The eyepieces adjust independently.
4. Hold the PVS-7 with your left hand and fold the left eyecup over the eyepiece with your left thumb or
forenger to obstruct the view through the left eyepiece. Rotate the right diopter adjustment ring
until you are able to observe the clearest possible view through the image intensier screen.
5. Hold the PVS-7 with your right hand and fold the right eyecup over the eyepiece with your right
thumb or forenger to obstruct the view through the right eyepiece. Rotate the left diopter adjust-
ment ring until you are able to observe the clearest possible view through the image intensier
screen.
6. While looking through the device, readjust the objective lens assembly until the image becomes
sharp and clear.
FIGURE 310. FLIPUP HELMET MOUNT